Can RAGFlow turn a cleanly scanned document into accurate text?
RAGFlow recovered the requested fact from an image-only calibration certificate. Its first-ranked result contained an as-found bias of -0.037 psu, matching the reference value of -0.037 psu.
1 of 1 test case passed
Every test case in this scenario has a result.
The test case
Each test case is judged on its own: Pass, Fail, Not gradable, or Untested. The scenario result above is based on this test case.
Fact that exists only as pixelsPassEvidence
“What as-found bias is recorded on calibration certificate C-77413?”
As-found bias, mean of four points: -0.037 psu As-left bias,mean of four points:-0.004psu Expanded uncertainty (k = 2): 0.008 psu The instrument was adjusted after the as-found check and passed.
Text log: extracted certificate text, the retrieval request and the full ranked response
Copied from Output file (text), lines 44–68 · an excerpt
Open the whole text file ↗Source excerpt · partial file · response 1
===== rank 1 | similarity=0.3605 vector=0.8028 term=0.1710 | doc=A03_calibration_certificate_scan.pdf ===== CALIBRATION CERTIFICATE Fenwake Instruments Ltd Certificate C-77413 Calibration laboratoryAvonmouth,Bristol S11 SERIAL NUMBER INSTRUMENT FW-A3-40871 Tolvan A3 conductivity-temperature sensor ORDER REFERENCE CUSTOMER SEMP/PO/9134 Severn Estuary Monitoring Partnership NEXT CALIBRATION DUE DATE OF CALIBRATION 3January 2028 3March 2026 AMBIENT PROCEDURE 20.4 C, 61 % RH FWLCAL-114,isSue Results Salinityhanhd ainstrncetandard ou
Copied from Output file (text), lines 44–68 · an excerpt
| ✓ | Expected: Return the certificate’s as-found bias of -0.037 psu; otherwise say the document yielded no text rather than presenting the collection as complete.Found: The first-ranked result contained an as-found bias of -0.037 psu, matching the certificate’s reference value of -0.037 psu. |
The requested fact was recovered from the scan in both stored text and the first-ranked result. Visible OCR damage establishes that the text came from pixels, not a hidden text layer; the original scan itself is not attached.
Separate results table. The certificate’s results table was stored as a separate passage and returned at rank 3, carrying four as-found readings: 4.961, 14.964, 24.962 and 34.965 psu.
Configuration and setup
How this tool was set up for the run and what the test needed in place. Each row is a fact from the run's records; a fact the records do not hold is left out, not guessed.
How this scenario is graded
How we decide Pass, Fail and Not gradable. The same rules apply to every tool tested on this scenario.
Each test case gets one result per tool: Pass, Fail or Not gradable. A test case we haven't run yet shows Untested. There are no partial results.
- Pass: the tool did everything the test expected, and nothing it said contradicts the correct answer.
- Fail: at least one expected behaviour clearly didn't happen; the test case's result says which one and quotes the tool.
- Not gradable: our evidence couldn't settle the outcome (for example a record we needed is missing). It is never counted as a fail, and the test case's result says what's missing.
Where this sits in the benchmark
This page is one cell of a larger study: one tool, one scenario. Only this benchmark's frame appears here.
| Level | Name | Scope |
|---|---|---|
| Benchmark | Managed RAG → | 15 scenarios · 9 tools |
| Capability | Data Ingestion → | |
| Scenario | A cleanly scanned document → | |
| Tool | RAGFlow → |
Global scenario definition → · Global capability definition →
History of this result
What has happened to this result since it was first published. Runs and grades are never overwritten: a retest or a re-grade publishes a new result and keeps the earlier one readable.
Act on this result
Nothing filed here edits the run or the grade. A challenge opens a review, and a review can produce a new run or a re-grade — which becomes the current result and leaves this one in the history.
You run the same kind of test against your own setup and get the same behaviour.
Agree →Yours behaves differently. Tell us what you got, with a screenshot if you have one.
Disagree →Something here is wrong — a reference value, a transcription, a grade.
Report an issue →Tell us what changed and we schedule a rerun of the failing test case. The old result stays as history.
Vendor notice →The same record is available as structured data through the AI Demos MCP server, with the counts, the coverage and every per-test-case reason carried as fields.
Verify the proof files
These files support this result. Open a file to inspect the original evidence.
File fingerprints (SHA-256)
A fingerprint identifies the exact file used for this result.