AI Demos Research — the structured-intelligence platform. Every verdict on these pages opens to the execution behind it.
Graded 17 October 2026

Does Extend AI process scanned pages inside a digital PDF?

Extend AI converted the scanned worksheet alongside the digital pages without skipping it. The worksheet's readable values stayed in place, with nothing added.

1 of 1 test case passed

Every test case in this scenario has a result.

Pass rate100%1 of 1 gradable
Coverage1 of 1test case with a result
1PassDid everything it was expected to do.
0FailNo test case failed.
0Not gradableEvery result here could be graded.
0UntestedEvery test case in this scenario has a result.
The pass rate is a summary. The evidence is the test case below: what we sent, what we checked, what the tool returned, and the proof.

The test case

Each test case is judged on its own: Pass, Fail, Not gradable, or Untested. The scenario result above is based on this test case.

Mixed pages — scanned page not skippedPassEvidence
What we sent

We sent the complete 3-page PDF to Extend AI's document-to-Markdown API in one request using the default pipeline.

InputDocument (PDF)
Input PDF: a photographed worksheet between two digital service-report pages
Open the PDF ↗
What the tool returned

Kirkhollow Analytical Laboratories Ltd Service worksheet

FIELD SERVICE

Job reference
KAL-ESR-4471

Instrument serial
GK-2214-77

Engineer
R. Tarbert

Date
29 January 2026

CHECKS AND READINGS

Flow cell condition on arrivalFouled, inner face
Flow cell pressure after service2.4 bar
Zero drift over 30 minutes0.003 mg/l
Span recovery against standard99.4 per cent
Lamp hours at service8,140
ResultPass

Calibration certificate SR-4471/2

Analyser left in service on channel 2. Optical window to be inspected at the next visit.

TIME ON SITE

TIME ON SITE
Arrived29 January 2026, 09:15
Left29 January 2026, 13:40
Chargeable time4 hours 25 minutes
Next service dueJanuary 2027

RECEIVED BY

NameM. Cairney
PositionDuty operator, Vardenne Quay
Date29 January 2026

Engineer's signature

Service worksheet · KAL-ESR-4471

<page_number>Page 2 of 3</page_number>

Show the reply as returned (Markdown)
# Kirkhollow Analytical Laboratories Ltd Service worksheet

FIELD SERVICE

Job reference
KAL-ESR-4471

Instrument serial
GK-2214-77

Engineer
R. Tarbert

Date
29 January 2026

### CHECKS AND READINGS

<table>
<tbody>
<tr>
<td>Flow cell condition on arrival</td>
<td>Fouled, inner face</td>
</tr>
<tr>
<td>Flow cell pressure after service</td>
<td>2.4 bar</td>
</tr>
<tr>
<td>Zero drift over 30 minutes</td>
<td>0.003 mg/l</td>
</tr>
<tr>
<td>Span recovery against standard</td>
<td>99.4 per cent</td>
</tr>
<tr>
<td>Lamp hours at service</td>
<td>8,140</td>
</tr>
<tr>
<td>Result</td>
<td>Pass</td>
</tr>
</tbody>
</table>

### Calibration certificate SR-4471/2

Analyser left in service on channel 2. Optical window to be inspected at the next visit.

TIME ON SITE

<table>
<thead>
<tr>
<th colspan="2">TIME ON SITE</th>
</tr>
</thead>
<tbody>
<tr>
<td>Arrived</td>
<td>29 January 2026, 09:15</td>
</tr>
<tr>
<td>Left</td>
<td>29 January 2026, 13:40</td>
</tr>
<tr>
<td>Chargeable time</td>
<td>4 hours 25 minutes</td>
</tr>
<tr>
<td>Next service due</td>
<td>January 2027</td>
</tr>
</tbody>
</table>

### RECEIVED BY

<table>
<tbody>
<tr>
<td>Name</td>
<td>M. Cairney</td>
</tr>
<tr>
<td>Position</td>
<td>Duty operator, Vardenne Quay</td>
</tr>
<tr>
<td>Date</td>
<td>29 January 2026</td>
</tr>
</tbody>
</table>

Engineer's signature

Service worksheet · KAL-ESR-4471

<page_number>Page 2 of 3</page_number>

API response: three page sections, including the scanned worksheet as the longest

Copied from Captured file (JSON), parse_run › output › chunks 2 › content

Open the whole JSON file ↗
Output file (Markdown)
Returned Markdown: the scanned worksheet text between the digital pages
Markdown208 lines
Kirkhollow Analytical Laboratories Ltd

Job KAL-ESR-4471

# Equipment service report

CLIENT Braithe Estuary Partnership Estuary House, Vardenne Quay Braithe BR3 4LN

<table>
<tbody>
<tr>
<td>Job reference</td>
<td>KAL-ESR-4471</td>
</tr>
<tr>
<td>Date of visit</td>
<td>29 January 2026</td>
</tr>
<tr>
<td>Engineer</td>
<td>R. Tarbert</td>
</tr>
<tr>
<td>Instrument</td>
<td>Kestrel 400 turbidity analyser</td>
</tr>
<tr>
<td>Location</td>
<td>Vardenne Quay pumping station</td>
</tr>
<tr>
<td>Service interval</td>
<td>Twelve months</td>
</tr>
</tbody>
</table>

### Reported fault

Intermittent baseline noise on channel 2, reported by the Partnership on 21 January. The analyser had been running without attention since the annual service in January 2025.

### Work carried out

The flow cell was removed, stripped and cleaned, and the pump tubing set replaced. The optical window was found to be lightly fouled on the inner face; it was cleaned rather than replaced, and should be inspected again at the next visit. The analyser was recalibrated against the two-point standards and left running on channel 2 for an hour before the site was handed back. The completed worksheet is bound in as page 2 of this report.

KAL-ESR-4471

<page_number>Page 1 of 3</page_number>

# Kirkhollow Analytical Laboratories Ltd Service worksheet

FIELD SERVICE

Job reference
KAL-ESR-4471

Instrument serial
GK-2214-77

Engineer
R. Tarbert

Date
29 January 2026

### CHECKS AND READINGS

<table>
<tbody>
<tr>
<td>Flow cell condition on arrival</td>
<td>Fouled, inner face</td>
</tr>
<tr>
<td>Flow cell pressure after service</td>
<td>2.4 bar</td>
</tr>
<tr>
<td>Zero drift over 30 minutes</td>
<td>0.003 mg/l</td>
</tr>
<tr>
<td>Span recovery against standard</td>
<td>99.4 per cent</td>
</tr>
<tr>
<td>Lamp hours at service</td>
<td>8,140</td>
</tr>
<tr>
<td>Result</td>
<td>Pass</td>
</tr>
</tbody>
</table>

### Calibration certificate SR-4471/2

Analyser left in service on channel 2. Optical window to be inspected at the next visit.

TIME ON SITE

<table>
<thead>
<tr>
<th colspan="2">TIME ON SITE</th>
</tr>
</thead>
<tbody>
<tr>
<td>Arrived</td>
<td>29 January 2026, 09:15</td>
</tr>
<tr>
<td>Left</td>
<td>29 January 2026, 13:40</td>
</tr>
<tr>
<td>Chargeable time</td>
<td>4 hours 25 minutes</td>
</tr>
<tr>
<td>Next service due</td>
<td>January 2027</td>
</tr>
</tbody>
</table>

### RECEIVED BY

<table>
<tbody>
<tr>
<td>Name</td>
<td>M. Cairney</td>
</tr>
<tr>
<td>Position</td>
<td>Duty operator, Vardenne Quay</td>
</tr>
<tr>
<td>Date</td>
<td>29 January 2026</td>
</tr>
</tbody>
</table>

Engineer's signature

Service worksheet · KAL-ESR-4471

<page_number>Page 2 of 3</page_number>

Kirkhollow Analytical Laboratories Ltd

Job KAL-ESR-4471

### Parts fitted

<table>
<thead>
<tr>
<th>Part</th>
<th>Code</th>
<th>Quantity</th>
</tr>
</thead>
<tbody>
<tr>
<td>Pump tubing set</td>
<td>PT-114</td>
<td>1</td>
</tr>
<tr>
<td>Flow cell O-ring, 12 mm</td>
<td>OR-0912</td>
<td>2</td>
</tr>
<tr>
<td>Inlet filter, 40 micron</td>
<td>IF-4004</td>
<td>1</td>
</tr>
</tbody>
</table>

### Declaration

The work described in this report was carried out to the standard set out in the service agreement. The analyser was left in service and calibrated. The next annual service falls due in January 2027.

<table>
  <tbody><tr>
    <td>Engineer</td>
    <td>R. Tarbert</td>
  </tr>
  <tr>
    <td>Countersigned</td>
    <td>Dr A. J. Prosser</td>
  </tr>
  <tr>
    <td>Report issued</td>
    <td>2 February 2026</td>
  </tr>
</tbody></table>

KAL-ESR-4471

<page_number>Page 3 of 3</page_number>
Open the Markdown file ↗
Expected vs. Found
✓Expected: Include the scanned page's text in the Markdown alongside the digital pages, without skipping it.Found: Page 2 appeared between pages 1 and 3 with every readable worksheet value present; its 1,412-character section was the longest of the three.
Supporting proof
Cited values3 values from this file
parse_run › file
{ "object": "file", "id": "file_LjsRJMkLcPlBlXNa3OIGI", "name": "service_report_KAL-ESR-4471.pdf", "type": "PDF", "parentFileId": null, "metadata": { "pageCount": 3 }, "dataRetention": { "mode": "workspace_default", "status": "available" }, "createdAt": "2026-09-09T12:40:46.193Z", "updatedAt": "2026-09-09T12:40:56.647Z" }
parse_run › config
{ "engine": "parse_performance", "engineVersion": "2.0.0" }
parse_run › metrics
{ "processingTimeMs": 9341, "pageCount": 3 }
Why this result

With zero embedded text characters on page 2, its returned text demonstrates that the image-only page was processed, as required.

Also observed in this test case

Worksheet tables. The scanned worksheet's labels and values were returned together in structured HTML tables rather than flat lines.

Page markers. Each page ends with an explicit page-number marker.

Tested by Chandresh Bisht · evidence dated 9 September 2026

Configuration and setup

How this tool was set up for the run and what the test needed in place. Each row is a fact from the run's records; a fact the records do not hold is left out, not guessed.

Software that produced the output
Extend AI
Build or version
x-extend-api-version 2026-02-09; engine parse_performance 2.0.0
Plan or tier
free tier (10,000 starter credits, Pay As You Go)
Surface
API
Set up before the run
The complete service-report PDF, with a photographed worksheet between digital pages, had to be converted to Markdown in one pass using the default pipeline without tuning.
Tested
9 September 2026 · Chandresh Bisht

How this scenario is graded

How we decide Pass, Fail and Not gradable. The same rules apply to every tool tested on this scenario.

How results are decided

Each test case gets one result per tool: Pass, Fail or Not gradable. A test case we haven't run yet shows Untested. There are no partial results.

The rules
  • Pass: the tool did everything the test expected, and nothing it said contradicts the correct answer.
  • Fail: at least one expected behaviour clearly didn't happen; the test case's result says which one and quotes the tool.
  • Not gradable: our evidence couldn't settle the outcome (for example a record we needed is missing). It is never counted as a fail, and the test case's result says what's missing.

Where this sits in the benchmark

This page is one cell of a larger study: one tool, one scenario. Only this benchmark's frame appears here.

History of this result

What has happened to this result since it was first published. Runs and grades are never overwritten: a retest or a re-grade publishes a new result and keeps the earlier one readable.

from the publication record
18 November 2026First publishedConverting a complex PDF into clean Markdown with a hosted API v1

Act on this result

Nothing filed here edits the run or the grade. A challenge opens a review, and a review can produce a new run or a re-grade — which becomes the current result and leaves this one in the history.

This matches what I see

You run the same kind of test against your own setup and get the same behaviour.

Agree →
This does not match

Yours behaves differently. Tell us what you got, with a screenshot if you have one.

Disagree →
Point out an issue

Something here is wrong — a reference value, a transcription, a grade.

Report an issue →
Request a retest

On a newer build, a larger dataset, or your own setup.

Request a retest →
We have fixed this

Tell us what changed and we schedule a rerun of the failing test case. The old result stays as history.

Vendor notice →
Filed against this evidenceNothing yet. Challenges, counter-evidence and fix notices appear here with their outcome, and stay on the page after they are resolved.
Cite this result
aidemos.com/benchmarks/pdf-to-markdown-apis/results/extend-ai/a-document-mixing-digital-and-scanned-pages · 1 pass · 0 fail · coverage 1/1 · graded 2026-10-17

The same record is available as structured data through the AI Demos MCP server, with the counts, the coverage and every per-test-case reason carried as fields.

Verify the proof files

These files support this result. Open a file to inspect the original evidence.

Input · Document (PDF) ↗application/pdf · 356 KB
Output file (Markdown) ↗text/markdown · 4 KB
Captured file (JSON) ↗application/json · 52 KB
File fingerprints (SHA-256)

A fingerprint identifies the exact file used for this result.

Input · Document (PDF)096951b8eaf09740a926620943c7eb9b076e80144d76e7a90fb7f77056b6ef83
Output file (Markdown)f679963dd47993e283269f5f825498a241bbea5b8dc9e6d55de2c3f3dbfb20b5
Captured file (JSON)8a263fe0ad1ac9dc096feac119166083d5c5a67662b2bc85204e9987e44702ae