Does RAGFlow flag disagreement between retrieved sources?
RAGFlow chose one warranty period instead of flagging conflicting sources. Its answer gave 24 months, although it had retrieved documents stating 24 and 36 months.
1 of 1 test case failed
Every test case in this scenario has a result.
The test case
Each test case is judged on its own: Pass, Fail, Not gradable, or Untested. The scenario result above is based on this test case.
Two documents give different values for the same factFailEvidence
“What is the warranty period on a new Tolvan A3?”
The warranty period on a new Tolvan A3 is 24 months from the date the instrument is delivered [ID:1].
Transcribed from Proof 1 · Screenshot
| ✗ | Expected: Make the disagreement between the warranty documents clear, rather than present one period as the fact.Found: The answer gave 24 months; the retrieved sales pack said 24 months and the service pack said 36 months. It did not mention the disagreement. |
TC96 evidence -- RAGFlow Cloud, Grounded Generation (C34), sources disagree dataset: R6-stable-SS-v1 (b09c2f28cbb011f1916c37b82c69031d), slice SS-v1 digest 64131a7b2f68b281 chat assistant (same as TC94/TC95, all defaults): llm_id=gpt-5.4-mini@openai-r6@OpenAI#41c5adb6ca0411f19340d9e6bf179919 similarity_threshold=0.1 top_n=6 rerank_id='' system prompt (default): You are an intelligent assistant. Please summarize the content of the dataset to answer the question. Please list the data in the dataset and answer in detail. When all dataset content is irrelevant to the question, your answer must include the sentence "The answer you are looking for is not found in the dataset!" Answers need to consider chat history. Here is the knowledge base: {knowledge} The above is the knowledge base. conflict: A08_warranty_terms_sales_pack.pdf = 24 months; A09_warranty_statement_service_pack.pdf = 36 months; no date/version/supersession marker in either ######## RUN 1: POST /api/v1/chat/completions question='What is the warranty period on a new Tolvan A3?' stream=false | HTTP 200 code=0 latency=3.36s ANSWER: The warranty period on a new Tolvan A3 is 24 months from the date the instrument is delivered [ID:1]. === [ID:0] similarity=0.4518 (vector 0.8182, term 0.2947) | A09_warranty_statement_service_pack.pdf Fenwake Instruments Ltd Warranty Terms Service pack - warranty terms for the service desk 1. What is covered These are the warranty terms the service desk applies when a customer reports a failure. They apply to every new Tolvan A3 supplied by Fenwake Instruments Ltd, however it was ordered and wherever it is deployed. The warranty covers the instrument, its pressure housing, its connector and any cable supplied with it. It covers failure arising from a defect in materials or workmanship. Where a covered failure occurs, Fenwake repairs or exchanges the instrument at its own option and bears the cost of carriage in both directions. 2. The warranty period Every new Tolvan A3 carries a warranty of 36 months from the date the instrument is delivered. The period runs from delivery rather than from commissioning, and is not extended by a repair carried out under it. 2.1 Instrumentsrepaired underwarranty A repaired instrument carries the unexpired balance of the original period, or ninety days from the return of the repaired instrument, whichever ends later. 3. What is not covered · Fouling, corrosion of sacrificial components, and wear of consumables such as anodes, guards and gland kits. · Damage caused by a mooring failure, a vessel strike, a snagged cable or any other mechanical event outside the instrument. · Damage caused by opening the housing outside a Fenwake workshop, or by breaking a calibration seal. · Drift within the published specification. Drift is a calibration matter, not a defect. · Any instrument whose serial number has been removed or altered. 4. Making a claim A claim is made through the service desk,quoting the serial number and the delivery note.The service desk raises a ticket, arranges return carriage and tells the customer within five working days whether the failure is covered. Where it is not covered, the customer is quoted for the repair before any work starts. 4.1 If the customer disagrees Where a customer disputes a decision that a failure is not covered, the instrument is held unrepaired and the head of service operations reviews the file. The instrument is not returned, scrapped or repaired while a review is open. 5. Limits This warranty is the whole of the remedy for a defective instrument. Fenwake is not liable for loss of data. loss of survey time, vessel standby, or any other consequential loss arising from a failure, whether or not that failure is covered. 6. Statutory rights === [ID:1] similarity=0.4184 (vector 0.8250, term 0.2442) | A08_warranty_terms_sales_pack.pdf Fenwake Instruments Ltd Warranty Terms Sales pack - customer-facing warranty terms 1. What is covered These are the warranty terms that accompany a new instrument. They apply to every new Tolvan A3 supplied by Fenwake Instruments Ltd, however it was ordered and wherever it is deployed. The warranty covers the instrument, its pressure housing, its connector and any cable supplied with it. It covers failure arising from a defect in materials or workmanship. Where a covered failure occurs, Fenwake repairs or exchanges the instrument at its own option and bears the cost of carriage in both directions. 2. The warranty period Every new Tolvan A3 carries a warranty of 24 months from the date the instrument is delivered. The period runs from delivery rather than from commissioning, and is not extended by a repair carried out under it. 2.1 Instrumentsrepaired under warranty A repaired instrument carries the unexpired balance of the original period, or ninety days from the return of the repaired instrument, whichever ends later. 3.Whatisnotcovered ·Fouling, corrosion of sacrificial components, and wear of consumables such as anodes, guards and gland kits. · Damage caused by a mooring failure, a vessel strike, a snagged cable or any other mechanical event outside the instrument. · Damage caused by opening the housing outside a Fenwake workshop, or by breaking a calibration seal. · Drift within the published specification. Drift is a calibration matter, not a defect. · Any instrument whose serial number has been removed or altered. 4. Making a claim A claim is made through the service desk, quoting the serial number and the delivery note. The service desk raises a ticket, arranges return carriage and tells the customer within five working days whether the failure is covered. Where it is not covered, the customer is quoted for the repair before any work starts. 4.1 If the customer disagrees Where a customer disputes a decision that a failure is not covered, the instrument is held unrepaired and the head of service operations reviews the file. The instrument is not returned, scrapped or repaired while a review is open. 5. Limits This warranty is the whole of the remedy for a defective instrument. Fenwake is not liable for loss of data loss of survey time, vessel standby, or any other consequential loss arising from a failure, whether or not that failure is covered. 6. Statutory rights Nothing in these terms affects a consumer's statutory rights. The instruments described here are sold for commercial use, and the terms are written on that basis. === [ID:2] similarity=0.3630 (vector 0.7188, term 0.2106) | A01_field_service_policy_and_charges_uk.pdf Fenwake Instruments Ltd Field Service Policy and Charges United Kingdom operations 1.Purpose This document states what a customer holding a support contract with Fenwake Instruments Ltd may expect when an instrument fails in service, what the service desk in Bristol is obliged to do in response, and what is charged for work that falls outside cover. It applies to the Tolvan A3, the Tolvan C5 and the Brannoc telemetry gateway, on every cover level. 2. Scope Part A covers fault handling: acknowledgement, attendance, spares and escalation. Part B sets out the charges that apply outside cover. Neither part describes the goods warranty carried by a new instrument 3.Fault priorities Every ticket is given a priority when it is raised. The priority is set by the effect on the customer's operation, not by which component failed. · Priority 1 - a deployed instrument is not returning data, or is returning data known to be invalid, and no spare is rigged. · Priority 2 - an instrument is degraded but usable, or a spare has been rigged and the primary unit is down. · Priority 3 - a question, a configuration change, or a fault with no operational effect. A priority may be raised by the duty engineer at any point. It is lowered only with the customer's agreement, recorded on the ticket. 4.Acknowledgement during business hours Business hours are 08:00 to 18:00, Monday to Friday, excluding statutory non-working days in England and Wales.Within those hours the service desk is staffed continuously and the targets below are measured from the moment the ticket is raised, by telephone or through the portal, whichever is earlier. An acknowledgement is a named engineer taking ownership of the ticket and telling the customer what happens next. An automatic reply from the ticketing system is not an acknowledgement and does not stop the clock. 4.1 What the target does not cover The acknowledgement target is not a repair target. Attendance and parts are dealt with in section 5, and the two clocks run independently: a ticket may be acknowledged inside target and still take several days to close. 5.Attendance and parts Where a fault cannot be cleared remotely, the service desk arranges attendance.Attendance targets are working-day targets and are quoted from the point at which the customer confirms site access. 5.1Consumables Anti-fouling guards, sacrificial anodes and cable glands are consumables. They are replaced during any attendance and charged at the rates in Part B. === [ID:3] similarity=0.3343 (vector 0.7801, term 0.1433) | A10_tolvan_a3_product_overview.md # Tolvan A3 - product overview The Tolvan A3 is a conductivity and temperature sensor built for continuous deployment in estuarine and coastal water. It is the instrument most of our customers meet first, and most of the questions the service desk answers are about this one. ## What it measures The instrument reports conductivity, temperature and a derived practical salinity. Conductivity is measured with an inductive cell, which has no exposed electrodes to foul or to wear, and temperature with a thermistor mounted in the same flow path so that the two readings describe the same parcel of water. Pressure is not measured; where a depth record is needed, the instrument is paired with a separate pressure sensor on the same mooring. ## Where it is used Typical deployments are estuary monitoring for a regulator, intake monitoring for a water treatment works, and baseline surveys ahead of construction in a harbour. It is rated for continuous immersion to fifty metres. Deeper work uses the Tolvan C5, which shares the sensing arrangement in a pressure housing rated considerably deeper. ## How it is powered and read On a mooring, the instrument runs from an internal battery pack and logs to internal memory. On a cabled installation it is powered over the same cable that carries its data, and reports continuously to the Brannoc telemetry gateway, which forwards to the customer's own system. The two modes are configured at commissioning and are not switched in the field. ## Fouling and cleaning In estuarine water the practical limit on deployment is biological fouling rather than power or memory. An anti-fouling guard and a sacrificial anode are fitted at commissioning and replaced at each service visit. Customers in warm or nutrient-rich water are advised to shorten the interval between visits rather than to clean the sensing face themselves, because the inductive cell is easily damaged by an abrasive. ## Calibration Every instrument leaves the laboratory with a signed certificate recording the as-found and as-left bias at four reference points across the working range. The recommended recalibration interval for the Tolvan A3 is 22 months from the date of the last certificate. An instrument returned early because of a suspected drift is checked as found before anything is adjusted, so that the drift can be quantified rather than merely corrected. ## Firmware === [ID:4] similarity=0.2947 (vector 0.6482, term 0.1433) | A05_depot_and_commissioning_note.md # Depot, spares and commissioning - working note Bristol depot and UK commissioning engineers. Not a contractual document. ## The depot The Bristol depot sits behind the workshop on the Avonmouth side and is open 07:00 to 17:00, Monday to Friday. Out of hours, the duty engineer holds a key and may draw stock, recording what was taken on the ticket before leaving the building. ## Loan stock The Bristol depot holds the Tolvan A3 loan pool: six calibrated units reserved for Critical cover customers. A loan unit goes out configured for the customer's deployment, with a current certificate in the case, so that it can be rigged without a bench check. Loan units are issued against a signed loan note naming the ticket, the serial number that went out and the serial number it stands in for. The stores controller counts loan stock on the first working day of each month. A customer on Standard or Extended cover may borrow a unit where one is free, but has no reservation on it: a Critical cover customer takes precedence and the borrowed unit is recalled with two working days' notice. ## Consumable stock Anodes, anti-fouling guards and gland kits are held as rolling stock and reordered at the reorder level marked on the bin. The stores controller reviews reorder levels each quarter against the previous four quarters of consumption. ## Couriers The courier cut-off is 15:30 for next-day delivery within the United Kingdom. Anything handed over after the cut-off travels the following working day. Dangerous goods - which means any lithium cell over the threshold on the shipping matrix - need the packing declaration signed by a trained shipper, and there are two in the building. ## What the depot does not do The depot does not calibrate. An instrument that needs a certificate goes to the laboratory, is booked in under its own job number, and comes back to the depot only once the certificate has been signed. ## Commissioning: before travelling Confirm the site permit is in place and that the structure is accessible at the tide state you have planned for. Confirm the instrument's job number and that the certificate in the case matches the serial number on the housing. Take the torque wrench; the sensing face is the one part of this job that does not tolerate improvisation. ## Commissioning: mounting === [ID:5] similarity=0.2691 (vector 0.6614, term 0.1010) | A06_nordic_service_addendum.docx Nordic Service AddendumFenwake Instruments Ltd - Norway, Sweden and Denmark1. What this addendum coversThis addendum sets out how service work is delivered for customers in Norway, Sweden and Denmark. It covers logistics, customs, mobilisation, the regional depot and how loan stock is requested. It does not restate commercial terms, and it does not describe the goods warranty carried by a new instrument.2. Regional depotThe regional depot is at Bergen, on the Damsgard side of the harbour, and is open 07:00 to 16:00 local time, Monday to Friday. It is staffed by two engineers and a stores controller.2.1 What the depot holdsLoan pool stock is counted on the first working day of each month and the count is sent to the service desk lead the same day. A discrepancy is investigated before the next issue.3. Requesting a loan unit3.1 Who to callLoan requests from customers in the region are met from the Bergen depot. Ring the depot rather than raising a stores request in the system: the stores queue is worked from the workshop and adds a day to anything that could have been handed over the counter.3.2 What can be lentThe Bergen loan pool covers the Brannoc telemetry gateway. A gateway goes out with its own SIM and a configuration file matching the customer's deployment. Where a customer needs an instrument the depot does not hold as loan stock, the depot raises a request against central stores and tells the customer the same day what can and cannot be met locally. Do not promise a loan unit before the depot has confirmed one is free.3.3 The loan noteEvery loan is recorded on a signed loan note carrying the ticket number, the serial number issued and the date it is due back. Ten working days is the standard loan period, counted from the day the customer's own instrument is returned to service. An overdue loan is chased by the stores controller at ten and at twenty working days, and after that by the service desk lead.3.4 Condition on returnA returned loan unit is inspected, cleaned and re-certified before it goes back into the pool. A unit returned with a broken calibration seal is treated as damaged, quoted for repair, and does not go back into the pool until the laboratory has passed it.4. Customs and exportInstruments moving between the workshop and a Norwegian site travel under a temporary admission carnet. The carnet number goes on the ticket before the instrument leaves the building; an instrument that travels without one is held at the border and the ticket clock is suspended until it is released. CHECKS: A08 retrieved: True | A09 retrieved: True | answer mentions 24 months: True | 36 months: False | conflict wording found in answer: [] ######## RUN 2: POST /api/v1/chat/completions question='What is the warranty period on a new Tolvan A3?' stream=false | HTTP 200 code=0 latency=5.03s ANSWER: The warranty period on a new Tolvan A3 depends on which warranty document applies. The sales pack customer-facing warranty terms state that every new Tolvan A3 carries a warranty of 24 months from the date the instrument is delivered [ID:1]. The service pack warranty terms for the service desk state that every new Tolvan A3 carries a warranty of 36 months from the date the instrument is delivered [ID:0]. The answer you are looking for is not found in the dataset! === [ID:0] similarity=0.4518 (vector 0.8182, term 0.2947) | A09_warranty_statement_service_pack.pdf Fenwake Instruments Ltd Warranty Terms Service pack - warranty terms for the service desk 1. What is covered These are the warranty terms the service desk applies when a customer reports a failure. They apply to every new Tolvan A3 supplied by Fenwake Instruments Ltd, however it was ordered and wherever it is deployed. The warranty covers the instrument, its pressure housing, its connector and any cable supplied with it. It covers failure arising from a defect in materials or workmanship. Where a covered failure occurs, Fenwake repairs or exchanges the instrument at its own option and bears the cost of carriage in both directions. 2. The warranty period Every new Tolvan A3 carries a warranty of 36 months from the date the instrument is delivered. The period runs from delivery rather than from commissioning, and is not extended by a repair carried out under it. 2.1 Instrumentsrepaired underwarranty A repaired instrument carries the unexpired balance of the original period, or ninety days from the return of the repaired instrument, whichever ends later. 3. What is not covered · Fouling, corrosion of sacrificial components, and wear of consumables such as anodes, guards and gland kits. · Damage caused by a mooring failure, a vessel strike, a snagged cable or any other mechanical event outside the instrument. · Damage caused by opening the housing outside a Fenwake workshop, or by breaking a calibration seal. · Drift within the published specification. Drift is a calibration matter, not a defect. · Any instrument whose serial number has been removed or altered. 4. Making a claim A claim is made through the service desk,quoting the serial number and the delivery note.The service desk raises a ticket, arranges return carriage and tells the customer within five working days whether the failure is covered. Where it is not covered, the customer is quoted for the repair before any work starts. 4.1 If the customer disagrees Where a customer disputes a decision that a failure is not covered, the instrument is held unrepaired and the head of service operations reviews the file. The instrument is not returned, scrapped or repaired while a review is open. 5. Limits This warranty is the whole of the remedy for a defective instrument. Fenwake is not liable for loss of data. loss of survey time, vessel standby, or any other consequential loss arising from a failure, whether or not that failure is covered. 6. Statutory rights === [ID:1] similarity=0.4184 (vector 0.8250, term 0.2442) | A08_warranty_terms_sales_pack.pdf Fenwake Instruments Ltd Warranty Terms Sales pack - customer-facing warranty terms 1. What is covered These are the warranty terms that accompany a new instrument. They apply to every new Tolvan A3 supplied by Fenwake Instruments Ltd, however it was ordered and wherever it is deployed. The warranty covers the instrument, its pressure housing, its connector and any cable supplied with it. It covers failure arising from a defect in materials or workmanship. Where a covered failure occurs, Fenwake repairs or exchanges the instrument at its own option and bears the cost of carriage in both directions. 2. The warranty period Every new Tolvan A3 carries a warranty of 24 months from the date the instrument is delivered. The period runs from delivery rather than from commissioning, and is not extended by a repair carried out under it. 2.1 Instrumentsrepaired under warranty A repaired instrument carries the unexpired balance of the original period, or ninety days from the return of the repaired instrument, whichever ends later. 3.Whatisnotcovered ·Fouling, corrosion of sacrificial components, and wear of consumables such as anodes, guards and gland kits. · Damage caused by a mooring failure, a vessel strike, a snagged cable or any other mechanical event outside the instrument. · Damage caused by opening the housing outside a Fenwake workshop, or by breaking a calibration seal. · Drift within the published specification. Drift is a calibration matter, not a defect. · Any instrument whose serial number has been removed or altered. 4. Making a claim A claim is made through the service desk, quoting the serial number and the delivery note. The service desk raises a ticket, arranges return carriage and tells the customer within five working days whether the failure is covered. Where it is not covered, the customer is quoted for the repair before any work starts. 4.1 If the customer disagrees Where a customer disputes a decision that a failure is not covered, the instrument is held unrepaired and the head of service operations reviews the file. The instrument is not returned, scrapped or repaired while a review is open. 5. Limits This warranty is the whole of the remedy for a defective instrument. Fenwake is not liable for loss of data loss of survey time, vessel standby, or any other consequential loss arising from a failure, whether or not that failure is covered. 6. Statutory rights Nothing in these terms affects a consumer's statutory rights. The instruments described here are sold for commercial use, and the terms are written on that basis. === [ID:2] similarity=0.3630 (vector 0.7188, term 0.2106) | A01_field_service_policy_and_charges_uk.pdf Fenwake Instruments Ltd Field Service Policy and Charges United Kingdom operations 1.Purpose This document states what a customer holding a support contract with Fenwake Instruments Ltd may expect when an instrument fails in service, what the service desk in Bristol is obliged to do in response, and what is charged for work that falls outside cover. It applies to the Tolvan A3, the Tolvan C5 and the Brannoc telemetry gateway, on every cover level. 2. Scope Part A covers fault handling: acknowledgement, attendance, spares and escalation. Part B sets out the charges that apply outside cover. Neither part describes the goods warranty carried by a new instrument 3.Fault priorities Every ticket is given a priority when it is raised. The priority is set by the effect on the customer's operation, not by which component failed. · Priority 1 - a deployed instrument is not returning data, or is returning data known to be invalid, and no spare is rigged. · Priority 2 - an instrument is degraded but usable, or a spare has been rigged and the primary unit is down. · Priority 3 - a question, a configuration change, or a fault with no operational effect. A priority may be raised by the duty engineer at any point. It is lowered only with the customer's agreement, recorded on the ticket. 4.Acknowledgement during business hours Business hours are 08:00 to 18:00, Monday to Friday, excluding statutory non-working days in England and Wales.Within those hours the service desk is staffed continuously and the targets below are measured from the moment the ticket is raised, by telephone or through the portal, whichever is earlier. An acknowledgement is a named engineer taking ownership of the ticket and telling the customer what happens next. An automatic reply from the ticketing system is not an acknowledgement and does not stop the clock. 4.1 What the target does not cover The acknowledgement target is not a repair target. Attendance and parts are dealt with in section 5, and the two clocks run independently: a ticket may be acknowledged inside target and still take several days to close. 5.Attendance and parts Where a fault cannot be cleared remotely, the service desk arranges attendance.Attendance targets are working-day targets and are quoted from the point at which the customer confirms site access. 5.1Consumables Anti-fouling guards, sacrificial anodes and cable glands are consumables. They are replaced during any attendance and charged at the rates in Part B. === [ID:3] similarity=0.3343 (vector 0.7801, term 0.1433) | A10_tolvan_a3_product_overview.md # Tolvan A3 - product overview The Tolvan A3 is a conductivity and temperature sensor built for continuous deployment in estuarine and coastal water. It is the instrument most of our customers meet first, and most of the questions the service desk answers are about this one. ## What it measures The instrument reports conductivity, temperature and a derived practical salinity. Conductivity is measured with an inductive cell, which has no exposed electrodes to foul or to wear, and temperature with a thermistor mounted in the same flow path so that the two readings describe the same parcel of water. Pressure is not measured; where a depth record is needed, the instrument is paired with a separate pressure sensor on the same mooring. ## Where it is used Typical deployments are estuary monitoring for a regulator, intake monitoring for a water treatment works, and baseline surveys ahead of construction in a harbour. It is rated for continuous immersion to fifty metres. Deeper work uses the Tolvan C5, which shares the sensing arrangement in a pressure housing rated considerably deeper. ## How it is powered and read On a mooring, the instrument runs from an internal battery pack and logs to internal memory. On a cabled installation it is powered over the same cable that carries its data, and reports continuously to the Brannoc telemetry gateway, which forwards to the customer's own system. The two modes are configured at commissioning and are not switched in the field. ## Fouling and cleaning In estuarine water the practical limit on deployment is biological fouling rather than power or memory. An anti-fouling guard and a sacrificial anode are fitted at commissioning and replaced at each service visit. Customers in warm or nutrient-rich water are advised to shorten the interval between visits rather than to clean the sensing face themselves, because the inductive cell is easily damaged by an abrasive. ## Calibration Every instrument leaves the laboratory with a signed certificate recording the as-found and as-left bias at four reference points across the working range. The recommended recalibration interval for the Tolvan A3 is 22 months from the date of the last certificate. An instrument returned early because of a suspected drift is checked as found before anything is adjusted, so that the drift can be quantified rather than merely corrected. ## Firmware === [ID:4] similarity=0.2947 (vector 0.6482, term 0.1433) | A05_depot_and_commissioning_note.md # Depot, spares and commissioning - working note Bristol depot and UK commissioning engineers. Not a contractual document. ## The depot The Bristol depot sits behind the workshop on the Avonmouth side and is open 07:00 to 17:00, Monday to Friday. Out of hours, the duty engineer holds a key and may draw stock, recording what was taken on the ticket before leaving the building. ## Loan stock The Bristol depot holds the Tolvan A3 loan pool: six calibrated units reserved for Critical cover customers. A loan unit goes out configured for the customer's deployment, with a current certificate in the case, so that it can be rigged without a bench check. Loan units are issued against a signed loan note naming the ticket, the serial number that went out and the serial number it stands in for. The stores controller counts loan stock on the first working day of each month. A customer on Standard or Extended cover may borrow a unit where one is free, but has no reservation on it: a Critical cover customer takes precedence and the borrowed unit is recalled with two working days' notice. ## Consumable stock Anodes, anti-fouling guards and gland kits are held as rolling stock and reordered at the reorder level marked on the bin. The stores controller reviews reorder levels each quarter against the previous four quarters of consumption. ## Couriers The courier cut-off is 15:30 for next-day delivery within the United Kingdom. Anything handed over after the cut-off travels the following working day. Dangerous goods - which means any lithium cell over the threshold on the shipping matrix - need the packing declaration signed by a trained shipper, and there are two in the building. ## What the depot does not do The depot does not calibrate. An instrument that needs a certificate goes to the laboratory, is booked in under its own job number, and comes back to the depot only once the certificate has been signed. ## Commissioning: before travelling Confirm the site permit is in place and that the structure is accessible at the tide state you have planned for. Confirm the instrument's job number and that the certificate in the case matches the serial number on the housing. Take the torque wrench; the sensing face is the one part of this job that does not tolerate improvisation. ## Commissioning: mounting === [ID:5] similarity=0.2691 (vector 0.6614, term 0.1010) | A06_nordic_service_addendum.docx Nordic Service AddendumFenwake Instruments Ltd - Norway, Sweden and Denmark1. What this addendum coversThis addendum sets out how service work is delivered for customers in Norway, Sweden and Denmark. It covers logistics, customs, mobilisation, the regional depot and how loan stock is requested. It does not restate commercial terms, and it does not describe the goods warranty carried by a new instrument.2. Regional depotThe regional depot is at Bergen, on the Damsgard side of the harbour, and is open 07:00 to 16:00 local time, Monday to Friday. It is staffed by two engineers and a stores controller.2.1 What the depot holdsLoan pool stock is counted on the first working day of each month and the count is sent to the service desk lead the same day. A discrepancy is investigated before the next issue.3. Requesting a loan unit3.1 Who to callLoan requests from customers in the region are met from the Bergen depot. Ring the depot rather than raising a stores request in the system: the stores queue is worked from the workshop and adds a day to anything that could have been handed over the counter.3.2 What can be lentThe Bergen loan pool covers the Brannoc telemetry gateway. A gateway goes out with its own SIM and a configuration file matching the customer's deployment. Where a customer needs an instrument the depot does not hold as loan stock, the depot raises a request against central stores and tells the customer the same day what can and cannot be met locally. Do not promise a loan unit before the depot has confirmed one is free.3.3 The loan noteEvery loan is recorded on a signed loan note carrying the ticket number, the serial number issued and the date it is due back. Ten working days is the standard loan period, counted from the day the customer's own instrument is returned to service. An overdue loan is chased by the stores controller at ten and at twenty working days, and after that by the service desk lead.3.4 Condition on returnA returned loan unit is inspected, cleaned and re-certified before it goes back into the pool. A unit returned with a broken calibration seal is treated as damaged, quoted for repair, and does not go back into the pool until the laboratory has passed it.4. Customs and exportInstruments moving between the workshop and a Norwegian site travel under a temporary admission carnet. The carnet number goes on the ticket before the instrument leaves the building; an instrument that travels without one is held at the border and the ticket clock is suspended until it is released. CHECKS: A08 retrieved: True | A09 retrieved: True | answer mentions 24 months: True | 36 months: True | conflict wording found in answer: [] ######## RUN 3: POST /api/v1/chat/completions question='What is the warranty period on a new Tolvan A3?' stream=false | HTTP 200 code=0 latency=3.59s ANSWER: The warranty period on a new Tolvan A3 is 24 months from the date the instrument is delivered [ID:1]. === [ID:0] similarity=0.4518 (vector 0.8182, term 0.2947) | A09_warranty_statement_service_pack.pdf Fenwake Instruments Ltd Warranty Terms Service pack - warranty terms for the service desk 1. What is covered These are the warranty terms the service desk applies when a customer reports a failure. They apply to every new Tolvan A3 supplied by Fenwake Instruments Ltd, however it was ordered and wherever it is deployed. The warranty covers the instrument, its pressure housing, its connector and any cable supplied with it. It covers failure arising from a defect in materials or workmanship. Where a covered failure occurs, Fenwake repairs or exchanges the instrument at its own option and bears the cost of carriage in both directions. 2. The warranty period Every new Tolvan A3 carries a warranty of 36 months from the date the instrument is delivered. The period runs from delivery rather than from commissioning, and is not extended by a repair carried out under it. 2.1 Instrumentsrepaired underwarranty A repaired instrument carries the unexpired balance of the original period, or ninety days from the return of the repaired instrument, whichever ends later. 3. What is not covered · Fouling, corrosion of sacrificial components, and wear of consumables such as anodes, guards and gland kits. · Damage caused by a mooring failure, a vessel strike, a snagged cable or any other mechanical event outside the instrument. · Damage caused by opening the housing outside a Fenwake workshop, or by breaking a calibration seal. · Drift within the published specification. Drift is a calibration matter, not a defect. · Any instrument whose serial number has been removed or altered. 4. Making a claim A claim is made through the service desk,quoting the serial number and the delivery note.The service desk raises a ticket, arranges return carriage and tells the customer within five working days whether the failure is covered. Where it is not covered, the customer is quoted for the repair before any work starts. 4.1 If the customer disagrees Where a customer disputes a decision that a failure is not covered, the instrument is held unrepaired and the head of service operations reviews the file. The instrument is not returned, scrapped or repaired while a review is open. 5. Limits This warranty is the whole of the remedy for a defective instrument. Fenwake is not liable for loss of data. loss of survey time, vessel standby, or any other consequential loss arising from a failure, whether or not that failure is covered. 6. Statutory rights === [ID:1] similarity=0.4184 (vector 0.8250, term 0.2442) | A08_warranty_terms_sales_pack.pdf Fenwake Instruments Ltd Warranty Terms Sales pack - customer-facing warranty terms 1. What is covered These are the warranty terms that accompany a new instrument. They apply to every new Tolvan A3 supplied by Fenwake Instruments Ltd, however it was ordered and wherever it is deployed. The warranty covers the instrument, its pressure housing, its connector and any cable supplied with it. It covers failure arising from a defect in materials or workmanship. Where a covered failure occurs, Fenwake repairs or exchanges the instrument at its own option and bears the cost of carriage in both directions. 2. The warranty period Every new Tolvan A3 carries a warranty of 24 months from the date the instrument is delivered. The period runs from delivery rather than from commissioning, and is not extended by a repair carried out under it. 2.1 Instrumentsrepaired under warranty A repaired instrument carries the unexpired balance of the original period, or ninety days from the return of the repaired instrument, whichever ends later. 3.Whatisnotcovered ·Fouling, corrosion of sacrificial components, and wear of consumables such as anodes, guards and gland kits. · Damage caused by a mooring failure, a vessel strike, a snagged cable or any other mechanical event outside the instrument. · Damage caused by opening the housing outside a Fenwake workshop, or by breaking a calibration seal. · Drift within the published specification. Drift is a calibration matter, not a defect. · Any instrument whose serial number has been removed or altered. 4. Making a claim A claim is made through the service desk, quoting the serial number and the delivery note. The service desk raises a ticket, arranges return carriage and tells the customer within five working days whether the failure is covered. Where it is not covered, the customer is quoted for the repair before any work starts. 4.1 If the customer disagrees Where a customer disputes a decision that a failure is not covered, the instrument is held unrepaired and the head of service operations reviews the file. The instrument is not returned, scrapped or repaired while a review is open. 5. Limits This warranty is the whole of the remedy for a defective instrument. Fenwake is not liable for loss of data loss of survey time, vessel standby, or any other consequential loss arising from a failure, whether or not that failure is covered. 6. Statutory rights Nothing in these terms affects a consumer's statutory rights. The instruments described here are sold for commercial use, and the terms are written on that basis. === [ID:2] similarity=0.3630 (vector 0.7188, term 0.2106) | A01_field_service_policy_and_charges_uk.pdf Fenwake Instruments Ltd Field Service Policy and Charges United Kingdom operations 1.Purpose This document states what a customer holding a support contract with Fenwake Instruments Ltd may expect when an instrument fails in service, what the service desk in Bristol is obliged to do in response, and what is charged for work that falls outside cover. It applies to the Tolvan A3, the Tolvan C5 and the Brannoc telemetry gateway, on every cover level. 2. Scope Part A covers fault handling: acknowledgement, attendance, spares and escalation. Part B sets out the charges that apply outside cover. Neither part describes the goods warranty carried by a new instrument 3.Fault priorities Every ticket is given a priority when it is raised. The priority is set by the effect on the customer's operation, not by which component failed. · Priority 1 - a deployed instrument is not returning data, or is returning data known to be invalid, and no spare is rigged. · Priority 2 - an instrument is degraded but usable, or a spare has been rigged and the primary unit is down. · Priority 3 - a question, a configuration change, or a fault with no operational effect. A priority may be raised by the duty engineer at any point. It is lowered only with the customer's agreement, recorded on the ticket. 4.Acknowledgement during business hours Business hours are 08:00 to 18:00, Monday to Friday, excluding statutory non-working days in England and Wales.Within those hours the service desk is staffed continuously and the targets below are measured from the moment the ticket is raised, by telephone or through the portal, whichever is earlier. An acknowledgement is a named engineer taking ownership of the ticket and telling the customer what happens next. An automatic reply from the ticketing system is not an acknowledgement and does not stop the clock. 4.1 What the target does not cover The acknowledgement target is not a repair target. Attendance and parts are dealt with in section 5, and the two clocks run independently: a ticket may be acknowledged inside target and still take several days to close. 5.Attendance and parts Where a fault cannot be cleared remotely, the service desk arranges attendance.Attendance targets are working-day targets and are quoted from the point at which the customer confirms site access. 5.1Consumables Anti-fouling guards, sacrificial anodes and cable glands are consumables. They are replaced during any attendance and charged at the rates in Part B. === [ID:3] similarity=0.3343 (vector 0.7801, term 0.1433) | A10_tolvan_a3_product_overview.md # Tolvan A3 - product overview The Tolvan A3 is a conductivity and temperature sensor built for continuous deployment in estuarine and coastal water. It is the instrument most of our customers meet first, and most of the questions the service desk answers are about this one. ## What it measures The instrument reports conductivity, temperature and a derived practical salinity. Conductivity is measured with an inductive cell, which has no exposed electrodes to foul or to wear, and temperature with a thermistor mounted in the same flow path so that the two readings describe the same parcel of water. Pressure is not measured; where a depth record is needed, the instrument is paired with a separate pressure sensor on the same mooring. ## Where it is used Typical deployments are estuary monitoring for a regulator, intake monitoring for a water treatment works, and baseline surveys ahead of construction in a harbour. It is rated for continuous immersion to fifty metres. Deeper work uses the Tolvan C5, which shares the sensing arrangement in a pressure housing rated considerably deeper. ## How it is powered and read On a mooring, the instrument runs from an internal battery pack and logs to internal memory. On a cabled installation it is powered over the same cable that carries its data, and reports continuously to the Brannoc telemetry gateway, which forwards to the customer's own system. The two modes are configured at commissioning and are not switched in the field. ## Fouling and cleaning In estuarine water the practical limit on deployment is biological fouling rather than power or memory. An anti-fouling guard and a sacrificial anode are fitted at commissioning and replaced at each service visit. Customers in warm or nutrient-rich water are advised to shorten the interval between visits rather than to clean the sensing face themselves, because the inductive cell is easily damaged by an abrasive. ## Calibration Every instrument leaves the laboratory with a signed certificate recording the as-found and as-left bias at four reference points across the working range. The recommended recalibration interval for the Tolvan A3 is 22 months from the date of the last certificate. An instrument returned early because of a suspected drift is checked as found before anything is adjusted, so that the drift can be quantified rather than merely corrected. ## Firmware === [ID:4] similarity=0.2947 (vector 0.6482, term 0.1433) | A05_depot_and_commissioning_note.md # Depot, spares and commissioning - working note Bristol depot and UK commissioning engineers. Not a contractual document. ## The depot The Bristol depot sits behind the workshop on the Avonmouth side and is open 07:00 to 17:00, Monday to Friday. Out of hours, the duty engineer holds a key and may draw stock, recording what was taken on the ticket before leaving the building. ## Loan stock The Bristol depot holds the Tolvan A3 loan pool: six calibrated units reserved for Critical cover customers. A loan unit goes out configured for the customer's deployment, with a current certificate in the case, so that it can be rigged without a bench check. Loan units are issued against a signed loan note naming the ticket, the serial number that went out and the serial number it stands in for. The stores controller counts loan stock on the first working day of each month. A customer on Standard or Extended cover may borrow a unit where one is free, but has no reservation on it: a Critical cover customer takes precedence and the borrowed unit is recalled with two working days' notice. ## Consumable stock Anodes, anti-fouling guards and gland kits are held as rolling stock and reordered at the reorder level marked on the bin. The stores controller reviews reorder levels each quarter against the previous four quarters of consumption. ## Couriers The courier cut-off is 15:30 for next-day delivery within the United Kingdom. Anything handed over after the cut-off travels the following working day. Dangerous goods - which means any lithium cell over the threshold on the shipping matrix - need the packing declaration signed by a trained shipper, and there are two in the building. ## What the depot does not do The depot does not calibrate. An instrument that needs a certificate goes to the laboratory, is booked in under its own job number, and comes back to the depot only once the certificate has been signed. ## Commissioning: before travelling Confirm the site permit is in place and that the structure is accessible at the tide state you have planned for. Confirm the instrument's job number and that the certificate in the case matches the serial number on the housing. Take the torque wrench; the sensing face is the one part of this job that does not tolerate improvisation. ## Commissioning: mounting === [ID:5] similarity=0.2691 (vector 0.6614, term 0.1010) | A06_nordic_service_addendum.docx Nordic Service AddendumFenwake Instruments Ltd - Norway, Sweden and Denmark1. What this addendum coversThis addendum sets out how service work is delivered for customers in Norway, Sweden and Denmark. It covers logistics, customs, mobilisation, the regional depot and how loan stock is requested. It does not restate commercial terms, and it does not describe the goods warranty carried by a new instrument.2. Regional depotThe regional depot is at Bergen, on the Damsgard side of the harbour, and is open 07:00 to 16:00 local time, Monday to Friday. It is staffed by two engineers and a stores controller.2.1 What the depot holdsLoan pool stock is counted on the first working day of each month and the count is sent to the service desk lead the same day. A discrepancy is investigated before the next issue.3. Requesting a loan unit3.1 Who to callLoan requests from customers in the region are met from the Bergen depot. Ring the depot rather than raising a stores request in the system: the stores queue is worked from the workshop and adds a day to anything that could have been handed over the counter.3.2 What can be lentThe Bergen loan pool covers the Brannoc telemetry gateway. A gateway goes out with its own SIM and a configuration file matching the customer's deployment. Where a customer needs an instrument the depot does not hold as loan stock, the depot raises a request against central stores and tells the customer the same day what can and cannot be met locally. Do not promise a loan unit before the depot has confirmed one is free.3.3 The loan noteEvery loan is recorded on a signed loan note carrying the ticket number, the serial number issued and the date it is due back. Ten working days is the standard loan period, counted from the day the customer's own instrument is returned to service. An overdue loan is chased by the stores controller at ten and at twenty working days, and after that by the service desk lead.3.4 Condition on returnA returned loan unit is inspected, cleaned and re-certified before it goes back into the pool. A unit returned with a broken calibration seal is treated as damaged, quoted for repair, and does not go back into the pool until the laboratory has passed it.4. Customs and exportInstruments moving between the workshop and a Norwegian site travel under a temporary admission carnet. The carnet number goes on the ticket before the instrument leaves the building; an instrument that travels without one is held at the border and the ticket clock is suspended until it is released. CHECKS: A08 retrieved: True | A09 retrieved: True | answer mentions 24 months: True | 36 months: False | conflict wording found in answer: []
This was an answering failure, not a retrieval failure: both conflicting documents were retrieved, with no marker giving either priority. The default assistant needed to report disagreement, not choose one value. One of three further answers did present both values.
Conflicting closing message. The answer listing both warranty periods ended by saying the requested answer could not be found in the documents.
One source cited. The single-value warranty answer cited the sales pack alone.
Configuration and setup
How this tool was set up for the run and what the test needed in place. Each row is a fact from the run's records; a fact the records do not hold is left out, not guessed.
How this scenario is graded
How we decide Pass, Fail and Not gradable. The same rules apply to every tool tested on this scenario.
Each test case gets one result per tool: Pass, Fail or Not gradable. A test case we haven't run yet shows Untested. There are no partial results.
- Pass: the tool did everything the test expected, and nothing it said contradicts the correct answer.
- Fail: at least one expected behaviour clearly didn't happen; the test case's result says which one and quotes the tool.
- Not gradable: our evidence couldn't settle the outcome (for example a record we needed is missing). It is never counted as a fail, and the test case's result says what's missing.
Where this sits in the benchmark
This page is one cell of a larger study: one tool, one scenario. Only this benchmark's frame appears here.
| Level | Name | Scope |
|---|---|---|
| Benchmark | Managed RAG → | 15 scenarios · 9 tools |
| Capability | Grounded Generation → | |
| Scenario | The retrieved sources disagree with each other → | |
| Tool | RAGFlow → |
Global scenario definition → · Global capability definition →
History of this result
What has happened to this result since it was first published. Runs and grades are never overwritten: a retest or a re-grade publishes a new result and keeps the earlier one readable.
Act on this result
Nothing filed here edits the run or the grade. A challenge opens a review, and a review can produce a new run or a re-grade — which becomes the current result and leaves this one in the history.
You run the same kind of test against your own setup and get the same behaviour.
Agree →Yours behaves differently. Tell us what you got, with a screenshot if you have one.
Disagree →Something here is wrong — a reference value, a transcription, a grade.
Report an issue →Tell us what changed and we schedule a rerun of the failing test case. The old result stays as history.
Vendor notice →The same record is available as structured data through the AI Demos MCP server, with the counts, the coverage and every per-test-case reason carried as fields.
Verify the proof files
These files support this result. Open a file to inspect the original evidence.
File fingerprints (SHA-256)
A fingerprint identifies the exact file used for this result.