Does Vectara signal when an answer is unavailable in the knowledge base?
Vectara signaled the unavailable paid-parental-leave answer through clearly lower relevance scores. In a second default-reranker call with no context window specified, the top score was 0.0820, versus 0.9986 for an answerable question on the same documents.
1 of 1 test case passed
Every test case in this scenario has a result.
The test case
Each test case is judged on its own: Pass, Fail, Not gradable, or Untested. The scenario result above is based on this test case.
Reasonable question no document answersPassEvidence
Input 1 · Vectara default reranker: “How much paid parental leave does Fenwake give?”
Input 2 · Reranker: none: “How much paid parental leave does Fenwake give?”
Response 1 (Default reranker results) is the output of a separate run for Input 1.
Response 2 (No-rerank results) is the output of a separate run for Input 2.
Default reranker results rank=1 score=0.189521 document_id=A04_employee_handbook.docx page=None region=group Employee Handbook Fenwake Instruments Ltd - all locations 1. Working here This handbook sets out the terms that apply to everyone employed by Fenwake Instruments Ltd, whether based at the Bristol workshop, at the Avonmouth calibration laboratory, or working from a customer site or vessel. It forms part of your contract. Where a term is set out in your written statement of particulars and also here, the written statement governs. Hours of work Standard hours are 37.5 a week, worked between 08:00 and 18:00, Monday to Friday. ---------------------------------------------------------------------------------------------------- rank=2 score=0.028981 document_id=A09_warranty_statement_service_pack.pdf page=1 region=group They apply to every new Tolvan A3 supplied by Fenwake Instruments Ltd, however it was ordered and wherever it is deployed. The warranty covers the instrument, its pressure housing, its connector and any cable supplied with it. It covers failure arising from a defect in materials or workmanship. Where a covered failure occurs, Fenwake repairs or exchanges the instrument at its own option and bears the cost of carriage in both directions. The warranty period Every new Tolvan A3 carries a warranty of 36 months from the date the instrument is delivered. The period runs from delivery rather than from commissioning, and is not extended by a repair carried out under it. 2.1 Instruments repaired under warranty A repaired instrument carries the unexpired balance of the original period, or ninety days from the return of the repaired instrument, whichever ends later. ---------------------------------------------------------------------------------------------------- rank=3 score=0.028981 document_id=A08_warranty_terms_sales_pack.pdf page=1 region=group They apply to every new Tolvan A3 supplied by Fenwake Instruments Ltd, however it was ordered and wherever it is deployed. The warranty covers the instrument, its pressure housing, its connector and any cable supplied with it. It covers failure arising from a defect in materials or workmanship. Where a covered failure occurs, Fenwake repairs or exchanges the instrument at its own option and bears the cost of carriage in both directions. The warranty period Every new Tolvan A3 carries a warranty of 24 months from the date the instrument is delivered. The period runs from delivery rather than from commissioning, and is not extended by a repair carried out under it. 2.1 Instruments repaired under warranty A repaired instrument carries the unexpired balance of the original period, or ninety days from the return of the repaired instrument, whichever ends later. ---------------------------------------------------------------------------------------------------- rank=4 score=0.027481 document_id=A01_field_service_policy_and_charges_uk.pdf page=1 region=uk (anonymous) Fenwake Instruments Ltd Field Service Policy and Charges United Kingdom operations Purpose This document states what a customer holding a support contract with Fenwake Instruments Ltd may expect when an instrument fails in service, what the service desk in Bristol is obliged to do in response, and what is charged for work that falls outside cover. ---------------------------------------------------------------------------------------------------- rank=5 score=0.009486 document_id=A09_warranty_statement_service_pack.pdf page=2 region=group 4.1 If the customer disagrees Where a customer disputes a decision that a failure is not covered, the instrument is held unrepaired and the head of service operations reviews the file. The instrument is not returned, scrapped or repaired while a Service pack Page 1 Fenwake Instruments Ltd - Warranty Terms review is open. Limits This warranty is the whole of the remedy for a defective instrument. Fenwake is not liable for loss of data, loss of survey time, vessel standby, or any other consequential loss arising from a failure, whether or not that failure is covered. ---------------------------------------------------------------------------------------------------- rank=6 score=0.009449 document_id=A08_warranty_terms_sales_pack.pdf page=2 region=group 4.1 If the customer disagrees Where a customer disputes a decision that a failure is not covered, the instrument is held unrepaired and the head of service operations reviews the file. The instrument is not returned, scrapped or repaired while a review is open. Sales pack Page 1 Fenwake Instruments Ltd - Warranty Terms Limits This warranty is the whole of the remedy for a defective instrument. Fenwake is not liable for loss of data, loss of survey time, vessel standby, or any other consequential loss arising from a failure, whether or not that failure is covered. Statutory rights Nothing in these terms affects a consumer's statutory rights. ---------------------------------------------------------------------------------------------------- rank=7 score=0.005888 document_id=A08_warranty_terms_sales_pack.pdf page=2 region=group Sales pack Page 1 Fenwake Instruments Ltd - Warranty Terms Limits This warranty is the whole of the remedy for a defective instrument. Fenwake is not liable for loss of data, loss of survey time, vessel standby, or any other consequential loss arising from a failure, whether or not that failure is covered. Statutory rights Nothing in these terms affects a consumer's statutory rights. The instruments described here are sold for commercial use, and the terms are written on that basis. Sales pack Page 2 ---------------------------------------------------------------------------------------------------- rank=8 score=0.004628 document_id=A04_employee_handbook.docx page=None region=group Service operations will decline a request that would leave the duty engineer rota uncovered, and will say so within five working days so that alternative dates can be chosen. 3.2 Carry-over Up to five days of untaken annual leave may be carried into the next leave year, and must be taken by 30 June. Anything beyond five days is carried over only where leave could not be taken because of a business requirement, and only with the written agreement of a director. 3.3 Leave on leaving On termination, accrued and untaken annual leave is paid in the final salary payment. Where more leave has been taken than accrued, the balance is deducted from that payment. Sickness absence Report sickness to your line manager before 09:00 on the first day, by telephone rather than by message. Absence of seven calendar days or fewer is self-certified on return. ---------------------------------------------------------------------------------------------------- rank=9 score=0.001846 document_id=A09_warranty_statement_service_pack.pdf page=1 region=group Warranty Terms - Tolvan A3 Fenwake Instruments Ltd Warranty Terms Service pack - warranty terms for the service desk What is covered These are the warranty terms the service desk applies when a customer reports a failure. ---------------------------------------------------------------------------------------------------- rank=10 score=0.001579 document_id=A08_warranty_terms_sales_pack.pdf page=1 region=group Warranty Terms - Tolvan A3 Fenwake Instruments Ltd Warranty Terms Sales pack - customer-facing warranty terms What is covered These are the warranty terms that accompany a new instrument. ---------------------------------------------------------------------------------------------------- No-rerank results rank=1 score=0.676647 document_id=A04_employee_handbook.docx page=None region=group Service operations will decline a request that would leave the duty engineer rota uncovered, and will say so within five working days so that alternative dates can be chosen. 3.2 Carry-over Up to five days of untaken annual leave may be carried into the next leave year, and must be taken by 30 June. Anything beyond five days is carried over only where leave could not be taken because of a business requirement, and only with the written agreement of a director. 3.3 Leave on leaving On termination, accrued and untaken annual leave is paid in the final salary payment. Where more leave has been taken than accrued, the balance is deducted from that payment. Sickness absence Report sickness to your line manager before 09:00 on the first day, by telephone rather than by message. Absence of seven calendar days or fewer is self-certified on return. ---------------------------------------------------------------------------------------------------- rank=2 score=0.668708 document_id=A09_warranty_statement_service_pack.pdf page=2 region=group 4.1 If the customer disagrees Where a customer disputes a decision that a failure is not covered, the instrument is held unrepaired and the head of service operations reviews the file. The instrument is not returned, scrapped or repaired while a Service pack Page 1 Fenwake Instruments Ltd - Warranty Terms review is open. Limits This warranty is the whole of the remedy for a defective instrument. Fenwake is not liable for loss of data, loss of survey time, vessel standby, or any other consequential loss arising from a failure, whether or not that failure is covered. ---------------------------------------------------------------------------------------------------- rank=3 score=0.668708 document_id=A08_warranty_terms_sales_pack.pdf page=2 region=group 4.1 If the customer disagrees Where a customer disputes a decision that a failure is not covered, the instrument is held unrepaired and the head of service operations reviews the file. The instrument is not returned, scrapped or repaired while a review is open. Sales pack Page 1 Fenwake Instruments Ltd - Warranty Terms Limits This warranty is the whole of the remedy for a defective instrument. Fenwake is not liable for loss of data, loss of survey time, vessel standby, or any other consequential loss arising from a failure, whether or not that failure is covered. Statutory rights Nothing in these terms affects a consumer's statutory rights. ---------------------------------------------------------------------------------------------------- rank=4 score=0.660518 document_id=A09_warranty_statement_service_pack.pdf page=1 region=group They apply to every new Tolvan A3 supplied by Fenwake Instruments Ltd, however it was ordered and wherever it is deployed. The warranty covers the instrument, its pressure housing, its connector and any cable supplied with it. It covers failure arising from a defect in materials or workmanship. Where a covered failure occurs, Fenwake repairs or exchanges the instrument at its own option and bears the cost of carriage in both directions. The warranty period Every new Tolvan A3 carries a warranty of 36 months from the date the instrument is delivered. The period runs from delivery rather than from commissioning, and is not extended by a repair carried out under it. 2.1 Instruments repaired under warranty A repaired instrument carries the unexpired balance of the original period, or ninety days from the return of the repaired instrument, whichever ends later. ---------------------------------------------------------------------------------------------------- rank=5 score=0.660518 document_id=A08_warranty_terms_sales_pack.pdf page=1 region=group They apply to every new Tolvan A3 supplied by Fenwake Instruments Ltd, however it was ordered and wherever it is deployed. The warranty covers the instrument, its pressure housing, its connector and any cable supplied with it. It covers failure arising from a defect in materials or workmanship. Where a covered failure occurs, Fenwake repairs or exchanges the instrument at its own option and bears the cost of carriage in both directions. The warranty period Every new Tolvan A3 carries a warranty of 24 months from the date the instrument is delivered. The period runs from delivery rather than from commissioning, and is not extended by a repair carried out under it. 2.1 Instruments repaired under warranty A repaired instrument carries the unexpired balance of the original period, or ninety days from the return of the repaired instrument, whichever ends later. ---------------------------------------------------------------------------------------------------- rank=6 score=0.659651 document_id=A01_field_service_policy_and_charges_uk.pdf page=1 region=uk (anonymous) Fenwake Instruments Ltd Field Service Policy and Charges United Kingdom operations Purpose This document states what a customer holding a support contract with Fenwake Instruments Ltd may expect when an instrument fails in service, what the service desk in Bristol is obliged to do in response, and what is charged for work that falls outside cover. ---------------------------------------------------------------------------------------------------- rank=7 score=0.659651 document_id=A09_warranty_statement_service_pack.pdf page=1 region=group Warranty Terms - Tolvan A3 Fenwake Instruments Ltd Warranty Terms Service pack - warranty terms for the service desk What is covered These are the warranty terms the service desk applies when a customer reports a failure. ---------------------------------------------------------------------------------------------------- rank=8 score=0.659651 document_id=A08_warranty_terms_sales_pack.pdf page=1 region=group Warranty Terms - Tolvan A3 Fenwake Instruments Ltd Warranty Terms Sales pack - customer-facing warranty terms What is covered These are the warranty terms that accompany a new instrument. ---------------------------------------------------------------------------------------------------- rank=9 score=0.652331 document_id=A04_employee_handbook.docx page=None region=group Employee Handbook Fenwake Instruments Ltd - all locations 1. Working here This handbook sets out the terms that apply to everyone employed by Fenwake Instruments Ltd, whether based at the Bristol workshop, at the Avonmouth calibration laboratory, or working from a customer site or vessel. It forms part of your contract. Where a term is set out in your written statement of particulars and also here, the written statement governs. Hours of work Standard hours are 37.5 a week, worked between 08:00 and 18:00, Monday to Friday. ---------------------------------------------------------------------------------------------------- rank=10 score=0.652124 document_id=A08_warranty_terms_sales_pack.pdf page=2 region=group Sales pack Page 1 Fenwake Instruments Ltd - Warranty Terms Limits This warranty is the whole of the remedy for a defective instrument. Fenwake is not liable for loss of data, loss of survey time, vessel standby, or any other consequential loss arising from a failure, whether or not that failure is covered. Statutory rights Nothing in these terms affects a consumer's statutory rights. The instruments described here are sold for commercial use, and the terms are written on that basis. Sales pack Page 2 ----------------------------------------------------------------------------------------------------
Text output: passages and scores with and without reranking
Copied from Output file (text), lines 130–239
Open the text file ↗Copied from Output file (text), lines 14–123
| ✓ | Expected: Indicate no answer with empty results, an explicit no-match, or relevance scores clearly separated from an answerable question on the same documents.Found: No passage supplied or implied a paid-parental-leave figure. A second default-reranker call, with no context window specified, scored 0.0820 at the top; the answerable comparison scored 0.9986. |
An empty list was not required: clearly separated relevance scores also counted as a no-answer signal. The second default-reranker call provided that signal. Without reranking, 0.6766 versus 0.8348 for an answerable question would not have been enough alone.
Configuration and setup
How this tool was set up for the run and what the test needed in place. Each row is a fact from the run's records; a fact the records do not hold is left out, not guessed.
How this scenario is graded
How we decide Pass, Fail and Not gradable. The same rules apply to every tool tested on this scenario.
Each test case gets one result per tool: Pass, Fail or Not gradable. A test case we haven't run yet shows Untested. There are no partial results.
- Pass: the tool did everything the test expected, and nothing it said contradicts the correct answer.
- Fail: at least one expected behaviour clearly didn't happen; the test case's result says which one and quotes the tool.
- Not gradable: our evidence couldn't settle the outcome (for example a record we needed is missing). It is never counted as a fail, and the test case's result says what's missing.
Where this sits in the benchmark
This page is one cell of a larger study: one tool, one scenario. Only this benchmark's frame appears here.
| Level | Name | Scope |
|---|---|---|
| Benchmark | Managed RAG → | 15 scenarios · 9 tools |
| Capability | Retrieval → | |
| Scenario | Answer is not available in the knowledge base → | |
| Tool | Vectara → |
Global scenario definition → · Global capability definition → · Vectara product page →
History of this result
What has happened to this result since it was first published. Runs and grades are never overwritten: a retest or a re-grade publishes a new result and keeps the earlier one readable.
Act on this result
Nothing filed here edits the run or the grade. A challenge opens a review, and a review can produce a new run or a re-grade — which becomes the current result and leaves this one in the history.
You run the same kind of test against your own setup and get the same behaviour.
Agree →Yours behaves differently. Tell us what you got, with a screenshot if you have one.
Disagree →Something here is wrong — a reference value, a transcription, a grade.
Report an issue →Tell us what changed and we schedule a rerun of the failing test case. The old result stays as history.
Vendor notice →The same record is available as structured data through the AI Demos MCP server, with the counts, the coverage and every per-test-case reason carried as fields.
Verify the proof files
These files support this result. Open a file to inspect the original evidence.
File fingerprints (SHA-256)
A fingerprint identifies the exact file used for this result.