AI Demos Research — the structured-intelligence platform. Every verdict on these pages opens to the execution behind it.
Graded 9 October 2026

Does Vectara signal when an answer is unavailable in the knowledge base?

Vectara signaled the unavailable paid-parental-leave answer through clearly lower relevance scores. In a second default-reranker call with no context window specified, the top score was 0.0820, versus 0.9986 for an answerable question on the same documents.

1 of 1 test case passed

Every test case in this scenario has a result.

Pass rate100%1 of 1 gradable
Coverage1 of 1test case with a result
1PassDid everything it was expected to do.
0FailNo test case failed.
0Not gradableEvery result here could be graded.
0UntestedEvery test case in this scenario has a result.
The pass rate is a summary. The evidence is the test case below: what we sent, what we checked, what the tool returned, and the proof.

The test case

Each test case is judged on its own: Pass, Fail, Not gradable, or Untested. The scenario result above is based on this test case.

Reasonable question no document answersPassEvidence
What we sent

Input 1 · Vectara default reranker: “How much paid parental leave does Fenwake give?”

Input 2 · Reranker: none: “How much paid parental leave does Fenwake give?”

What the tool returned

Response 1 (Default reranker results) is the output of a separate run for Input 1.

Response 2 (No-rerank results) is the output of a separate run for Input 2.

Text
Default reranker results
rank=1 score=0.189521 document_id=A04_employee_handbook.docx page=None region=group
Employee Handbook Fenwake Instruments Ltd - all locations 1. Working here This handbook sets out the
terms that apply to everyone employed by Fenwake Instruments Ltd, whether based at the Bristol
workshop, at the Avonmouth calibration laboratory, or working from a customer site or vessel. It
forms part of your contract. Where a term is set out in your written statement of particulars and
also here, the written statement governs. Hours of work Standard hours are 37.5 a week, worked
between 08:00 and 18:00, Monday to Friday.
----------------------------------------------------------------------------------------------------
rank=2 score=0.028981 document_id=A09_warranty_statement_service_pack.pdf page=1 region=group
They apply to
every new Tolvan A3 supplied by Fenwake Instruments Ltd, however it was ordered and wherever it is
deployed. The warranty covers the instrument, its pressure housing, its connector and any cable
supplied with it. It
covers failure arising from a defect in materials or workmanship. Where a covered failure occurs,
Fenwake repairs or exchanges the instrument at its own option and bears the cost of carriage in both
directions. The warranty period
Every new Tolvan A3 carries a warranty of 36 months from the date the instrument is delivered. The
period runs from delivery rather than from commissioning, and is not extended by a repair carried
out
under it. 2.1 Instruments repaired under warranty
A repaired instrument carries the unexpired balance of the original period, or ninety days from the
return
of the repaired instrument, whichever ends later.
----------------------------------------------------------------------------------------------------
rank=3 score=0.028981 document_id=A08_warranty_terms_sales_pack.pdf page=1 region=group
They apply to every new Tolvan A3
supplied by Fenwake Instruments Ltd, however it was ordered and wherever it is deployed. The
warranty covers the instrument, its pressure housing, its connector and any cable supplied with it.
It
covers failure arising from a defect in materials or workmanship. Where a covered failure occurs,
Fenwake repairs or exchanges the instrument at its own option and bears the cost of carriage in both
directions. The warranty period
Every new Tolvan A3 carries a warranty of 24 months from the date the instrument is delivered. The
period runs from delivery rather than from commissioning, and is not extended by a repair carried
out
under it. 2.1 Instruments repaired under warranty
A repaired instrument carries the unexpired balance of the original period, or ninety days from the
return
of the repaired instrument, whichever ends later.
----------------------------------------------------------------------------------------------------
rank=4 score=0.027481 document_id=A01_field_service_policy_and_charges_uk.pdf page=1 region=uk
(anonymous) Fenwake Instruments Ltd Field Service Policy and Charges United Kingdom operations
Purpose
This document states what a customer holding a support contract with Fenwake Instruments Ltd may
expect when an instrument fails in service, what the service desk in Bristol is obliged to do in
response,
and what is charged for work that falls outside cover.
----------------------------------------------------------------------------------------------------
rank=5 score=0.009486 document_id=A09_warranty_statement_service_pack.pdf page=2 region=group
4.1 If the customer disagrees
Where a customer disputes a decision that a failure is not covered, the instrument is held
unrepaired and
the head of service operations reviews the file. The instrument is not returned, scrapped or
repaired while a Service pack
Page 1 Fenwake Instruments Ltd - Warranty Terms review is open. Limits
This warranty is the whole of the remedy for a defective instrument. Fenwake is not liable for loss
of data,
loss of survey time, vessel standby, or any other consequential loss arising from a failure, whether
or not
that failure is covered.
----------------------------------------------------------------------------------------------------
rank=6 score=0.009449 document_id=A08_warranty_terms_sales_pack.pdf page=2 region=group
4.1 If the customer disagrees
Where a customer disputes a decision that a failure is not covered, the instrument is held
unrepaired and
the head of service operations reviews the file. The instrument is not returned, scrapped or
repaired while a
review is open. Sales pack
Page 1 Fenwake Instruments Ltd - Warranty Terms Limits
This warranty is the whole of the remedy for a defective instrument. Fenwake is not liable for loss
of data,
loss of survey time, vessel standby, or any other consequential loss arising from a failure, whether
or not
that failure is covered. Statutory rights
Nothing in these terms affects a consumer's statutory rights.
----------------------------------------------------------------------------------------------------
rank=7 score=0.005888 document_id=A08_warranty_terms_sales_pack.pdf page=2 region=group
Sales pack
Page 1 Fenwake Instruments Ltd - Warranty Terms Limits
This warranty is the whole of the remedy for a defective instrument. Fenwake is not liable for loss
of data,
loss of survey time, vessel standby, or any other consequential loss arising from a failure, whether
or not
that failure is covered. Statutory rights
Nothing in these terms affects a consumer's statutory rights. The instruments described here are
sold for
commercial use, and the terms are written on that basis. Sales pack
Page 2
----------------------------------------------------------------------------------------------------
rank=8 score=0.004628 document_id=A04_employee_handbook.docx page=None region=group
Service operations will decline a request that would leave the duty engineer rota uncovered, and
will say so within five working days so that alternative dates can be chosen. 3.2 Carry-over Up to
five days of untaken annual leave may be carried into the next leave year, and must be taken by 30
June. Anything beyond five days is carried over only where leave could not be taken because of a
business requirement, and only with the written agreement of a director. 3.3 Leave on leaving On
termination, accrued and untaken annual leave is paid in the final salary payment. Where more leave
has been taken than accrued, the balance is deducted from that payment. Sickness absence Report
sickness to your line manager before 09:00 on the first day, by telephone rather than by message.
Absence of seven calendar days or fewer is self-certified on return.
----------------------------------------------------------------------------------------------------
rank=9 score=0.001846 document_id=A09_warranty_statement_service_pack.pdf page=1 region=group
Warranty Terms - Tolvan A3 Fenwake Instruments Ltd Warranty Terms Service pack - warranty terms for
the service desk What is covered
These are the warranty terms the service desk applies when a customer reports a failure.
----------------------------------------------------------------------------------------------------
rank=10 score=0.001579 document_id=A08_warranty_terms_sales_pack.pdf page=1 region=group
Warranty Terms - Tolvan A3 Fenwake Instruments Ltd Warranty Terms Sales pack - customer-facing
warranty terms What is covered
These are the warranty terms that accompany a new instrument.
----------------------------------------------------------------------------------------------------

No-rerank results
rank=1 score=0.676647 document_id=A04_employee_handbook.docx page=None region=group
Service operations will decline a request that would leave the duty engineer rota uncovered, and
will say so within five working days so that alternative dates can be chosen. 3.2 Carry-over Up to
five days of untaken annual leave may be carried into the next leave year, and must be taken by 30
June. Anything beyond five days is carried over only where leave could not be taken because of a
business requirement, and only with the written agreement of a director. 3.3 Leave on leaving On
termination, accrued and untaken annual leave is paid in the final salary payment. Where more leave
has been taken than accrued, the balance is deducted from that payment. Sickness absence Report
sickness to your line manager before 09:00 on the first day, by telephone rather than by message.
Absence of seven calendar days or fewer is self-certified on return.
----------------------------------------------------------------------------------------------------
rank=2 score=0.668708 document_id=A09_warranty_statement_service_pack.pdf page=2 region=group
4.1 If the customer disagrees
Where a customer disputes a decision that a failure is not covered, the instrument is held
unrepaired and
the head of service operations reviews the file. The instrument is not returned, scrapped or
repaired while a Service pack
Page 1 Fenwake Instruments Ltd - Warranty Terms review is open. Limits
This warranty is the whole of the remedy for a defective instrument. Fenwake is not liable for loss
of data,
loss of survey time, vessel standby, or any other consequential loss arising from a failure, whether
or not
that failure is covered.
----------------------------------------------------------------------------------------------------
rank=3 score=0.668708 document_id=A08_warranty_terms_sales_pack.pdf page=2 region=group
4.1 If the customer disagrees
Where a customer disputes a decision that a failure is not covered, the instrument is held
unrepaired and
the head of service operations reviews the file. The instrument is not returned, scrapped or
repaired while a
review is open. Sales pack
Page 1 Fenwake Instruments Ltd - Warranty Terms Limits
This warranty is the whole of the remedy for a defective instrument. Fenwake is not liable for loss
of data,
loss of survey time, vessel standby, or any other consequential loss arising from a failure, whether
or not
that failure is covered. Statutory rights
Nothing in these terms affects a consumer's statutory rights.
----------------------------------------------------------------------------------------------------
rank=4 score=0.660518 document_id=A09_warranty_statement_service_pack.pdf page=1 region=group
They apply to
every new Tolvan A3 supplied by Fenwake Instruments Ltd, however it was ordered and wherever it is
deployed. The warranty covers the instrument, its pressure housing, its connector and any cable
supplied with it. It
covers failure arising from a defect in materials or workmanship. Where a covered failure occurs,
Fenwake repairs or exchanges the instrument at its own option and bears the cost of carriage in both
directions. The warranty period
Every new Tolvan A3 carries a warranty of 36 months from the date the instrument is delivered. The
period runs from delivery rather than from commissioning, and is not extended by a repair carried
out
under it. 2.1 Instruments repaired under warranty
A repaired instrument carries the unexpired balance of the original period, or ninety days from the
return
of the repaired instrument, whichever ends later.
----------------------------------------------------------------------------------------------------
rank=5 score=0.660518 document_id=A08_warranty_terms_sales_pack.pdf page=1 region=group
They apply to every new Tolvan A3
supplied by Fenwake Instruments Ltd, however it was ordered and wherever it is deployed. The
warranty covers the instrument, its pressure housing, its connector and any cable supplied with it.
It
covers failure arising from a defect in materials or workmanship. Where a covered failure occurs,
Fenwake repairs or exchanges the instrument at its own option and bears the cost of carriage in both
directions. The warranty period
Every new Tolvan A3 carries a warranty of 24 months from the date the instrument is delivered. The
period runs from delivery rather than from commissioning, and is not extended by a repair carried
out
under it. 2.1 Instruments repaired under warranty
A repaired instrument carries the unexpired balance of the original period, or ninety days from the
return
of the repaired instrument, whichever ends later.
----------------------------------------------------------------------------------------------------
rank=6 score=0.659651 document_id=A01_field_service_policy_and_charges_uk.pdf page=1 region=uk
(anonymous) Fenwake Instruments Ltd Field Service Policy and Charges United Kingdom operations
Purpose
This document states what a customer holding a support contract with Fenwake Instruments Ltd may
expect when an instrument fails in service, what the service desk in Bristol is obliged to do in
response,
and what is charged for work that falls outside cover.
----------------------------------------------------------------------------------------------------
rank=7 score=0.659651 document_id=A09_warranty_statement_service_pack.pdf page=1 region=group
Warranty Terms - Tolvan A3 Fenwake Instruments Ltd Warranty Terms Service pack - warranty terms for
the service desk What is covered
These are the warranty terms the service desk applies when a customer reports a failure.
----------------------------------------------------------------------------------------------------
rank=8 score=0.659651 document_id=A08_warranty_terms_sales_pack.pdf page=1 region=group
Warranty Terms - Tolvan A3 Fenwake Instruments Ltd Warranty Terms Sales pack - customer-facing
warranty terms What is covered
These are the warranty terms that accompany a new instrument.
----------------------------------------------------------------------------------------------------
rank=9 score=0.652331 document_id=A04_employee_handbook.docx page=None region=group
Employee Handbook Fenwake Instruments Ltd - all locations 1. Working here This handbook sets out the
terms that apply to everyone employed by Fenwake Instruments Ltd, whether based at the Bristol
workshop, at the Avonmouth calibration laboratory, or working from a customer site or vessel. It
forms part of your contract. Where a term is set out in your written statement of particulars and
also here, the written statement governs. Hours of work Standard hours are 37.5 a week, worked
between 08:00 and 18:00, Monday to Friday.
----------------------------------------------------------------------------------------------------
rank=10 score=0.652124 document_id=A08_warranty_terms_sales_pack.pdf page=2 region=group
Sales pack
Page 1 Fenwake Instruments Ltd - Warranty Terms Limits
This warranty is the whole of the remedy for a defective instrument. Fenwake is not liable for loss
of data,
loss of survey time, vessel standby, or any other consequential loss arising from a failure, whether
or not
that failure is covered. Statutory rights
Nothing in these terms affects a consumer's statutory rights. The instruments described here are
sold for
commercial use, and the terms are written on that basis. Sales pack
Page 2
----------------------------------------------------------------------------------------------------

Text output: passages and scores with and without reranking

Copied from Output file (text), lines 130–239

Open the text file ↗

Copied from Output file (text), lines 14–123

Expected vs. Found
✓Expected: Indicate no answer with empty results, an explicit no-match, or relevance scores clearly separated from an answerable question on the same documents.Found: No passage supplied or implied a paid-parental-leave figure. A second default-reranker call, with no context window specified, scored 0.0820 at the top; the answerable comparison scored 0.9986.
Supporting proof
Proof 1Screenshot
Notebook screenshot: the second default-reranker call and its answerable-question score comparison
Open original ↗
Proof 2Screenshot
Notebook screenshot: scores without reranking compared with an answerable question
Open original ↗
Why this result

An empty list was not required: clearly separated relevance scores also counted as a no-answer signal. The second default-reranker call provided that signal. Without reranking, 0.6766 versus 0.8348 for an answerable question would not have been enough alone.

Tested by Vivek Tomar · evidence dated 9 September 2026

Configuration and setup

How this tool was set up for the run and what the test needed in place. Each row is a fact from the run's records; a fact the records do not hold is left out, not guessed.

Software that produced the output
Vectara
Build or version
v2
Surface
API
Set up before the run
Fenwake’s documents had to contain neither a direct nor an implied answer to the question about how much paid parental leave it provides.
Search
10 results
Tested
9 September 2026 · Vivek Tomar

How this scenario is graded

How we decide Pass, Fail and Not gradable. The same rules apply to every tool tested on this scenario.

How results are decided

Each test case gets one result per tool: Pass, Fail or Not gradable. A test case we haven't run yet shows Untested. There are no partial results.

The rules
  • Pass: the tool did everything the test expected, and nothing it said contradicts the correct answer.
  • Fail: at least one expected behaviour clearly didn't happen; the test case's result says which one and quotes the tool.
  • Not gradable: our evidence couldn't settle the outcome (for example a record we needed is missing). It is never counted as a fail, and the test case's result says what's missing.

Where this sits in the benchmark

This page is one cell of a larger study: one tool, one scenario. Only this benchmark's frame appears here.

LevelNameScope
BenchmarkManaged RAG →15 scenarios · 9 tools
CapabilityRetrieval →
ScenarioAnswer is not available in the knowledge base →
ToolVectara →

History of this result

What has happened to this result since it was first published. Runs and grades are never overwritten: a retest or a re-grade publishes a new result and keeps the earlier one readable.

from the publication record
13 November 2026First publishedManaged RAG v1

Act on this result

Nothing filed here edits the run or the grade. A challenge opens a review, and a review can produce a new run or a re-grade — which becomes the current result and leaves this one in the history.

This matches what I see

You run the same kind of test against your own setup and get the same behaviour.

Agree →
This does not match

Yours behaves differently. Tell us what you got, with a screenshot if you have one.

Disagree →
Point out an issue

Something here is wrong — a reference value, a transcription, a grade.

Report an issue →
Request a retest

On a newer build, a larger dataset, or your own setup.

Request a retest →
We have fixed this

Tell us what changed and we schedule a rerun of the failing test case. The old result stays as history.

Vendor notice →
Filed against this evidenceNothing yet. Challenges, counter-evidence and fix notices appear here with their outcome, and stay on the page after they are resolved.
Cite this result
aidemos.com/benchmarks/managed-rag/results/vectara/answer-is-not-available-in-the-knowledge-base · 1 pass · 0 fail · coverage 1/1 · graded 2026-10-09

The same record is available as structured data through the AI Demos MCP server, with the counts, the coverage and every per-test-case reason carried as fields.

Verify the proof files

These files support this result. Open a file to inspect the original evidence.

Output file (text) ↗text/plain; charset=utf-8 · 16 KB
Proof 1 · Screenshot ↗image/png · 190 KB
Proof 2 · Screenshot ↗image/png · 392 KB
File fingerprints (SHA-256)

A fingerprint identifies the exact file used for this result.

Output file (text)763bd1e872a626b8d525c2c0c3f3782fc3452566351a221b24ab74d040a27f79
Proof 1 · Screenshotda674dc3af8eb283dedf445560a0698182a1164c3cfc54e058fa1dee1988ea6e
Proof 2 · Screenshota3548552e40c3b76506d8bfa9edc61a8fc0ee2ab5504b5efe92561a2d7f7b63f